guide-flow Specification
Purpose
Provide the patient-facing visit guidance experience for Pu Rui Smart Hospital Mini Program V2.0: guidance tab/list, detail process, visit code, document carriers, evaluation and AI guide entry. The module restores old guidance APIs and new page-aiguide/page-guide/page-guide-detail layouts while keeping real AI recommendation, refund/reschedule, payment, insurance and IM/TRTC write operations outside this module.
Requirements
Requirement: Guide List Page
The system SHALL provide a visit guidance tab page that restores the new page-guide layout and the old guidance list behavior.
Scenario: Load guidance list for current patient
- GIVEN the current hospital has
guideHospConfig enabled and a current patient exists
- WHEN the user opens the guide tab
- THEN the page SHALL request guidance list data through
17050049
- AND the page SHALL show visit code, process cards, hospital actions, real reminder information when returned, and list records.
- AND the page SHALL NOT show static weather or reminder mock data when no real source is returned.
Scenario: Guidance feature unavailable
- GIVEN the current hospital has not enabled guidance
- WHEN the user opens the guide tab
- THEN the page SHALL show an unavailable state and SHALL NOT call guidance list APIs.
Scenario: Guidance unread badge
- GIVEN a current patient exists
- WHEN the guide tab loads or refreshes
- THEN the system SHALL request unread count through
01010035
- AND sync
triageUnreadMessageCount to the custom tab bar settings.
Requirement: Guide Detail Page
The system SHALL provide a visit guidance detail page that restores the new page-guide-detail layout and old detail process behavior.
Scenario: Load detail and process categories
- GIVEN a guide record
admID
- WHEN the user opens detail
- THEN the page SHALL request base detail through
17050050
- AND request process categories through
01010032
- AND request category details through
01010033.
Scenario: Safe document and operation boundaries
- GIVEN the detail contains prescription, exam, refund, reschedule or payment-related entries
- WHEN the user taps those entries
- THEN the page SHALL show safe entry, disabled, or construction feedback
- AND SHALL NOT perform real refund, reschedule, payment, insurance, IM/TRTC or document payment write operations.
Requirement: Guide Evaluation
The system SHALL support guidance evaluation status query and submission according to the legacy source behavior, and SHALL treat only an explicit completed status as already evaluated. Boolean/string false, N, null, an absent status, and unrecognized statuses MUST NOT disable the evaluation form by default.
Scenario: Normalize an explicit evaluated status
- GIVEN
01010040 returns the legacy completed marker status: 'Y'
- WHEN the guide detail loads the evaluation record
- THEN the system SHALL display the record as evaluated
- AND SHALL disable rating, content editing, and duplicate submission.
Scenario: Normalize an eligible evaluation status
- GIVEN
01010040 returns N, boolean/string false, boolean/string true, null, no status, or an unrecognized status
- WHEN the guide detail loads the evaluation record
- THEN the system SHALL display the record as pending evaluation
- AND SHALL keep rating and content inputs available without issuing a submission request.
Scenario: Preserve submission failure input
- GIVEN a record is pending evaluation and the user has entered a rating and content
- WHEN the real
01010039 submission fails in an authorized manual test
- THEN the system SHALL preserve the entered rating and content
- AND SHALL not mark the record evaluated solely because the request failed.
Requirement: AI Guide Entry
The system SHALL provide an AI guide entry that restores the new page-aiguide interaction without producing medical diagnosis.
Scenario: AI guide interface not connected
- GIVEN the user selects a crowd and enters symptoms
- WHEN the user submits guide information before a real AI guide interface is connected
- THEN the page SHALL show unavailable feedback
- AND SHALL NOT show static, rule-based, mock department hints, science cards, diagnosis, treatment or medication conclusions.
Scenario: Connect AI guide to registration
- GIVEN a real recommendation interface is not connected
- WHEN the user opens the AI guide entry
- THEN the page SHALL keep the entry available for future integration
- AND SHALL NOT navigate with mock department context.